Modbus Master/Slave to PROFIBUS DPV1 Master Gateway

5104-MCM-PDPMV1

The ProLinx Modbus Master/Slave to PROFIBUS DPV1 Master gateway creates a powerful connection between devices on a Modbus serial network and PROFIBUS DP slave devices. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one PROFIBUS Master DB9F port.

The Modbus protocol supports both Master and Slave implementations. All Modbus serial ports are individually configurable, providing a choice of Modbus RTU or Modbus ASCII serial protocol support.

The PROFIBUS DPV1 Master protocol supports complete Master specifications according to IEC 61158 Version 1 on either a single or multiple Master network. The gateway offers both cyclic and acyclic data transfers from PROFIBUS DPV1 slaves, as well as cyclic data transfers from DPV0 slaves.

Funcionalidades e Beneficios

Powerful network integration

  • Allows movement of data between dissimilar networks using two communication protocols on one gateway
  • Protocols share access to a common memory database to exchange data between networks
  •  View diagnostic data for both networks from a single configuration/debug port

Modbus slave protocol interface

  • Emulate Modbus slave device on each individually-configurable application port
  • Supports Modbus RTU and Modbus ASCII protocol versions
  • Floating point data movement supported, including support for Enron, Daniel®, and other  implementations
  •  Suitable for SCADA and field device interface applications

PROFIBUS DPV1 Master protocol interface

  • Supports cyclic communications in V0 and both cyclic and acyclic communications in V1

Applications

The MCM-PDPMV1 gateways are the ideal solution for the many applications where Modbus connectivity can be used to integrate a PROFIBUS DP Slave device into a system. The Modbus Master/Slave gateway is a powerful gateway designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the gateway provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the gateway are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing . 

Especificações

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

Downloads

ProSoft Configuration Builder (PCB)
MCM PDPMV1 Datasheet 279,21 kB Última modificação 24/08/2016
MCM Driver Manual 835,78 kB Última modificação 10/12/2009
PDPMV1 Protocol Manual 3,04 MB Última modificação 08/02/2017

Protocolos

MCM Protocol Specification


The Modbus protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.


Protocol Specifications

The Modbus driver provides extensive support for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud rate, etc.).

General Parameters - Modbus Protocol

Communication parameters

Baud Rate: 110 to 115K baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds

Error Checking

RTU mode (binary) with CRC-16
ASCII mode with LRC error checking

Floating Point

Floating point data movement supported, including configurable support for Enron implementation

Function Codes

1: Read Output Status
2: Read Input Status
3: Read Multiple Data Registers
4: Read Input Registers
5: Write Single Bit
6: Write Single Data Register
15: Write Multiple Bits
16: Write Multiple Data Register

Modbus Master

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count.

Polling of command list

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Node address

1 to 247 (software selectable)


PDPMV1 Protocol Specification


The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.

The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.

  • Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB)
  • Project-unique GSD file import library
  • Monitoring and Modification of process data and DPV1 acyclic data
  • Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices
  • Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network
  • Automatic project documentation
  • Automatic Bus Parameter calculation
  • Online slave diagnostics
  • Supports all standardized baud rates, up to 12Mbps
  • Supports extended diagnostic data (DPV1)
  • Auto baud detection at all valid PROFIBUS DPV1 rates
  • Multiple modules can be placed in a single rack
  • CRC checksum determination of slave configuration consistency to processor
  • Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold
  • FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM)

PROFIBUS Master Specifications

  • Up to 125 Slaves can be connected with a repeater
  • Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data
  • Supports Extended Diagnostic Data
  • RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter
  • Acyclic communications (DPV1), Read and Write
  • Alarm Handling (DPV1)
  • Supports Sync and Freeze commands
  • Supports PROFIdrive 3.1 compliant parameter read and write operations
  • Supports Multicast and Broadcast telegrams (DPV1)

PROFIBUS Master Port

  • DB-9F Optically Isolated RS-485
  • Ready, Run, Error and Token LED Indicators
  • PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers

Protocol Specifications

The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.


Certificações

CB Safety 35,78 kB Última modificação 27/08/2012
CE Mark 92,34 kB Última modificação 28/02/2013
Korean KC Registration 851,60 kB Última modificação 22/02/2013
Russian GOST-R 7,07 MB Última modificação 22/02/2013
GOST-R Declaration of Conformity 6,68 MB Última modificação 22/02/2013
UL/cUL; Class 1, Div 2 1,08 MB Última modificação 02/07/2013
UL/cUL; Class 1, Div 2 (Canada) 1,10 MB Última modificação 02/07/2013