5304-MBP-PDPMV1-Right

Modbus Plus to PROFIBUS DPV1 Master Gateway

5304-MBP-PDPMV1

The ProLinx Modbus Plus to PROFIBUS DPV1 Master Gateway creates a powerful connection between devices on a Modbus Plus network and a PROFIBUS slave device. This stand-alone DIN-rail mounted protocol gateway provides one Modbus Plus configurable DB9F port and one PROFIBUS DPV1 Master configurable DB9F port.

The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.

The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.

Funcionalidades e Beneficios

Applications

The MBP-PDPMV1 modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the PROFIBUS DPV1 device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Aplicações

The MBP-PDPMV1 modules are the ideal solution for the many applications where Modbus Plus connectivity can be used to integrate a PROFIBUS DPV1 slave device into a system. The Modbus Plus gateway is a powerful module designed with both Master and Slave support, enabling easy connection to other Modbus Plus devices (Modicon processors and many others). In combination with the PROFIBUS DPV1 device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Especificações

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

Downloads

ProSoft Configuration Builder (PCB)
MBP PDPMV1 Datasheet 259,14 kB Última modificação 01/03/2012
PROFIBUS comDTM Datasheet 143,67 kB Última modificação 11/03/2010
MBP Protocol Manual 715,75 kB Última modificação 03/08/2017
PDPMV1 Protocol Manual 3,04 MB Última modificação 08/02/2017
PROFIBUS comDTM Quick Start Guide 695,02 kB Última modificação 12/05/2010

Protocolos

MBP Protocol Specification


The Modbus Plus protocol driver supports both Master and Slave implementations of the protocol on the DB9 Female Modbus Plus port. The Modbus Plus port is fully configurable.


Protocol Specifications

The Modbus Plus protocol driver exists in dual Modbus Plus Ports (MBP). The driver can be configured on an individual port basis as either a master or a slave to interface with other Modbus Plus devices.

General Parameters

Modbus Function Codes

3: Read Multiple Data Registers (MSTR 2)
16: Write Multiple Data Register (MSTR 1)
Global data read (32 words per node max.)
Global data write (32 words per node max.)

Address Scope

1 to 64

Modbus Plus Functioning as a Master

Command List

Up to 200 commands on the master port, fully configurable for function, slave address, register to/from addressing and word count

Polling of command list

Configurable polling of command list, including continuous read or write commands and write on change of data (Function Code 16 Write command only)"

Modbus Plus Functioning as a Slave

Node address

1 to 64 (software selectable)


PDPMV1 Protocol Specification


The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.

The ProLinx PDPMV1 PROFIBUS Master module acts as a PROFIBUS network scanner, transferring Input and Output data between PROFIBUS devices and the network.

  • Master Busview configuration interface via included ProSoft Configuration Builder software (see PSW-PCB)
  • Project-unique GSD file import library
  • Monitoring and Modification of process data and DPV1 acyclic data
  • Multi-drop on a PROFIBUS DPV1 network drop with other compatible devices
  • Ability to be used with a repeater as a PROFIBUS Master with PROFIBUS PA slaves on the network
  • Automatic project documentation
  • Automatic Bus Parameter calculation
  • Online slave diagnostics
  • Supports all standardized baud rates, up to 12Mbps
  • Supports extended diagnostic data (DPV1)
  • Auto baud detection at all valid PROFIBUS DPV1 rates
  • Multiple modules can be placed in a single rack
  • CRC checksum determination of slave configuration consistency to processor
  • Master Status LED Indicators for Operations, Network Drop Communication, Master Token-Hold
  • FDT/DTM PROFIBUS master transport communication DTM software included (see PSW-CDTM-PDPM)

PROFIBUS Master Specifications

  • Up to 125 Slaves can be connected with a repeater
  • Up to 1536 cyclic bytes (768 words) input and 1536 bytes (768 words) output data
  • Supports Extended Diagnostic Data
  • RS-485 optically isolated PROFIBUS Interface with on board DC-DC converter
  • Acyclic communications (DPV1), Read and Write
  • Alarm Handling (DPV1)
  • Supports Sync and Freeze commands
  • Supports PROFIdrive 3.1 compliant parameter read and write operations
  • Supports Multicast and Broadcast telegrams (DPV1)

PROFIBUS Master Port

  • DB-9F Optically Isolated RS-485
  • Ready, Run, Error and Token LED Indicators
  • PROFIBUS DPV1 RS-485 interface with a 9-pin D shell female connector and isolated Opto-Couplers

Protocol Specifications

The PROFIBUS DP Master protocol driver supports complete Master specifications according to IEC 61158 on either a Mono-Master or Multi-Master network. The module supports the DPV1 specification.


Certificações

Ex Certificate (ATEX Directive) 114,27 kB Última modificação 11/11/2013
CB Safety 35,78 kB Última modificação 27/08/2012
CE Mark 92,33 kB Última modificação 28/02/2013
Russian GOST-R 7,07 MB Última modificação 22/02/2013
GOST-R Declaration of Conformity 6,68 MB Última modificação 22/02/2013
UL/cUL; Class 1, Div 2 1,08 MB Última modificação 02/07/2013
UL/cUL; Class 1, Div 2 (Canada) 1,10 MB Última modificação 02/07/2013